Smoke curtain wall is a passive fire protection equipment used in most countries in the world. Its purpose is to control the spread of fire caused by smoke spread. There are three basic categories: fixed smoke curtain wall, flap type smoke curtain wall and rolling curtain type hang wallL (smoke curtain). The main body of the rolling curtain type smoke retaining wall is the smoke retaining cloth.
Glass fiber coated silica tape is usually used for smoke curtain wall cloth, and its quality depends on several factors: the quality of cloth and the quality of glue. The use of high-quality alkali free glass fiber cloth is not only the guarantee of the strength of the curtain cloth, but also the guarantee of delaying embrittlement under high temperature; and the use of high-quality silica gel is the guarantee that the curtain wall will not burn at 600 ℃!
    BS EN The basic requirements of 12101-1-2005 + A1-2006 standard for smoke screen wall detection are as follows: after passing the preliminary air permeability and strength test, two sets of smoke screen walls, 3M * 6m and 3M * 10m, shall be provided. First, 2000 times of winding test shall be conducted. After passing the test, a 3M * 3M smoke screen wall shall be cut from the smoke screen wall which has been wound for 2000 times for fire resistance test. The fire resistance test is 600 ℃ and a half Hours, maintain fire integrity.
Beijing feipufu's customers have carried out the annual re inspection of the smoke curtain wall in Singapore this year. Beijing feipufu Engineering Technology Co., Ltd. has provided the curtain cloth for the smoke curtain wall. The customers have sewed and manufactured machinery, transmission and control equipment by themselves, and sent them to Singapore for sealing test, and passed the test smoothly.
BS EN 12101-1-2005 + A1-2006 standard has been adopted in Europe, Southeast Asia and many other regions. Passing the test of this standard means that smoke curtain wall engineering projects can be implemented in these areas.
Beijing feipufu has completed the textile and coating production lines of high-temperature textiles, and has complete fire-resistant and strength laboratories. The technical team will launch new research and development projects every year, and has many patent technologies in the field of heat insulation, heat preservation, sealing and fire prevention.
Do fire prevention is to do conscience, do insulation is to do merit!

April 18, 2017

Beijing feipufu glass fiber silicone casing for aerospace service
Fire proof shutter for a large chemical enterprise in Beijing

Last

Next

Beijing feipufu curtain wall cloth has passed the test of BS EN 12101-1-2005 + A1-2006 standard again

​BS EN The basic requirements of 12101-1-2005 + A1-2006 standard for smoke screen wall detection are as follows: after passing the preliminary air permeability and strength test, two sets of smoke screen walls, 3M * 6m and 3M * 10m, shall be provided. First, 2000 times of winding test shall be conducted. After passing the test, a 3M * 3M smoke screen wall shall be cut from the smoke screen wall which has been wound for 2000 times for fire resistance test. The fire resistance test is 600 ℃ and a half Hours, maintain fire integrity.

Add time: